Typ. starting time with Us
< 250 ms (when controlled via A1)
Rated control circuit supply voltage US
20.4 V DC ... 26.4 V DC
24 V DC -15 % / +10 %
Rated control supply current IS
Application
Antivalent signal generator
Magnetic switch
Safety door
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typ. starting time with U<sub>s</sub>
< 250 ms (when controlled via A1)
Typical release time
< 20 ms (when controlled via A1 or S12 and S13.)
Restart time
1 s (Boot time, after switching on the supply voltage)
Maximum power dissipation for nominal condition
3 W (U<sub>S</sub> = 26.4 V, I<sub>L</sub>² = 36 A², P<sub>Total max</sub> = 1.2 W + 1.8 W)
Rated surge voltage/insulation
Rated control circuit supply voltage U<sub>S</sub>
20.4 V DC ... 26.4 V DC
24 V DC -15 % / +10 %
Rated control supply current I<sub>S</sub>
Power consumption at U<sub>S</sub>
Inrush current
< 10 mA
< 20 mA (typ. with U<sub>S</sub>)
4.5 A (Δt < 120 µs at U<sub>s</sub>)
max. 6 A
min. 3 mA
Filter time
1 ms (at A1 in the event of voltage dips at U<sub>s</sub>)
max. 1.5 ms (Test pulse width of low test pulses)
Test pulse rate = 5 x Test pulse width
Protective circuit
Serial protection against polarity reversal
Suppressor diode
Surge protection; Suppressor diode
Description of the input
non-safety-related
safety-related sensor inputs
Input voltage range "0" signal
0 V DC ... 5 V DC (for safe Off; at S12)
Input voltage range "1" signal
Input current range "0" signal
0 mA ... 2 mA (for safe Off; at S12)
Max. permissible overall conductor resistance
Current consumption
< 10 mA
< 5 mA (with U<sub>s</sub>/I<sub>x </sub>to S12)
Output description
non-safety-related
safety-related N/O contacts
Number of outputs
1 (digital, PNP)
1 (undelayed)
Switching voltage
max. 250 V AC/DC
min. 12 V AC/DC
Limiting continuous current
Sq. Total current
36 A<sup>2</sup> (observe derating)
Mechanical service life
10x 10<sup>6</sup> cycles
Output fuse
4 A gL/gG (for low-demand applications)
6 A gL/gG
Voltage
22 V DC (U<sub>s</sub> - 2 V)
Maximum inrush current
500 mA (Δt = 1 ms at U<sub>s</sub>)