EMC note
EMC: class A product, see manufacturer's declaration in the download area
Configuration
App
DIP switches
Software
Electrical isolation between input and output
Typical cold point errors
Maximum temperature coefficient
Transmission error thermocouples
0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
0.2 % * 600 K / set measuring range; 0.2 % > 600 K (B, R, S, A1, A2, A3)
0.4% * 600 K / set measuring range; 0.4% > 600 K (B, R, S, A1, A2, A3); Highspeed Mode
Standards/regulations
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-6-4
GB/T 3836.1
GB/T 3836.3
IEC/EN 61010-1
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption
32.7 mA (24 V DC)
66.8 mA (12 V DC)
Power consumption
≤ 850 mW (at I<sub>OUT</sub> = 20 mA, 9.6 V DC, 600 Ω load)
Configurable/programmable
Input voltage range
- 500 mV ... 500 mV (can be set via software)
Sensor types that can be used (TC)
B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range
-250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
≥ 50 K
Temperature measuring range: Type B thermocouple
Temperature measuring range: Type E thermocouple
Temperature measuring range: Type J thermocouple
Temperature measuring range: Type K thermocouple
Temperature measuring range: Type N thermocouple
Temperature measuring range: Type R thermocouple
Temperature measuring range: Type S thermocouple
Temperature measuring range: Type T thermocouple
Temperature measuring range: Type L thermocouple
Temperature measuring range: Type U thermocouple
Temperature measuring range: Type A1 GOST thermocouple
Temperature measuring range: Type A2 GOST thermocouple
Temperature measuring range: Type A3 GOST thermocouple
Temperature measuring range: Type M GOST thermocouple
Temperature measuring range: Type L GOST thermocouple
Voltage output signal
0 V ... 10 V (via DIP switch)
0 V ... 10.5 V (can be set via software)
0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
10 V ... 0 V (via DIP switch)
Max. voltage output signal
Current output signal
0 mA ... 20 mA (via DIP switch)
0 mA ... 21 mA (can be set via software)
20 mA ... 0 mA (via DIP switch)
20 mA ... 4 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
Max. current output signal
Load/output load voltage output
Load/output load current output