EMC note
EMC: class A product, see manufacturer's declaration in the download area
Input voltage range in reference to UN
Typical input current at UN
Application
Class I, Division 2
potentially explosive areas
Mechanical service life
approx. 2x 10<sup>7</sup> cycles
Date of last data management
Maximum power dissipation for nominal condition
Test voltage (Winding/contact)
2.5 kV<sub>rms</sub> (50 Hz, 1 min., winding/contact)
Test voltage (Contact/contact)
2 kV<sub>rms</sub> (50 Hz, 1 min., contact/contact)
Nominal input voltage U<sub>N</sub>
Input voltage range
96 V AC ... 144 V AC (20 °C)
Input voltage range in reference to U<sub>N</sub>
Typical input current at U<sub>N</sub>
Typical release time range
Operating voltage display
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
16 A (20 ms, N/O contacts)
Interrupting rating (ohmic load) max.
108 W (at 60 V DC)
120 W (at 24 V DC)
124 W (at 48 V DC)
1250 VA (for 250 V AC)
48 W (at 220 V DC)
52 W (at 110 V DC)
Switching capacity
0.11 A (at 250 V, DC13)
0.22 A (at 120 V, DC13)
1 A (at 240 V, AC15)
1.5 A (at 120 V, AC15)
1.5 A (at 24 V, AC15)
2 A (at 24 V, DC13)
Conductor cross-section rigid
Conductor cross-section flexible
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
Conductor cross-section AWG
26 ... 16 (flexible)
26 ... 16 (solid)