Reverse polarity protection
Rated insulation voltage
30 V AC/DC
40 V AC/DC
50 V AC/DC
Voltage input signal
19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Fuse
5 A (replaceable), slow-blow 250 V AC
Polarization and surge protection
Maximum switching voltage
30 V DC (2 A)
50 V AC (2 A)
50 V DC (0.22 A)
Max. current output signal
Output voltage
Input voltage - max 0.8 V at 3.75 A
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section flexible (2 conductors with same cross section)
0.25 mm² ... 0.34 mm² (TWIN ferrule without plastic sleeve)
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross-section AWG
20 ... 16 (TWIN ferrule with plastic sleeve)
24 ... 14
24 ... 22 (TWIN ferrule without plastic sleeve)
Status display
1 x red LED (error)
2x green LEDs (PWR1 and PWR2)
Depth NS 35/7,5
114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)
Flammability rating according to UL 94 (Housing)
Ambient temperature (operation)
-40 °C ... 42 °C
-40 °C ... 48 °C
-40 °C ... 54 °C
-40 °C ... 60 °C
-40 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Altitude
≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
Height range
> 2000 m ... 3000 m
> 3000 m ... 4000 m
> 4000 m ... 5000 m
Certificate
2021122303114198
CE-compliant
DNV GL TAA0000AG
IECEx IBE 08.0004X
PxCIF08ATEX2865625X
Identification
Class I, Div. 2, Groups A, B, C, D T5
Class I, Zone 2, Group IIC T5
Ex ec nC IIC T4 Gc
UL 61010 Listed
II 3 G Ex ec nC IIC T4 Gc
Enclosure
Required protection according to the Rules shall be provided upon installation on board
Electromagnetic compatibility
Conformance with EMC directive
Note
When being exposed to interference, there may be minimal deviations.
Standards/regulations
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-6-4
GB/T 3836.1
GB/T 3836.3
GB/T 3836.8
Designation
Conducted interferences
Electromagnetic RF field
Fast transients (burst)