Typ. starting time with Us
typ. 250 ms (with Us / when controlled via A1)
Rated control circuit supply voltage US
Application
Emergency stop
Safety door
Rated control supply current IS
typ. 70 mA (at U<sub>S</sub>)
Mechanical service life
10x 10<sup>6</sup> cycles
approx. 10<sup>7</sup> cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typical response time
typ. 150 ms (For U<sub>s </sub>autostart)
Typ. starting time with U<sub>s</sub>
typ. 250 ms (with Us / when controlled via A1)
Typical release time
typ. 20 ms (At Us on demand via sensor circuit)
typ. 45 ms (At Us/on demand via A1)
Recovery time
1 s (following demand of the safety function)
Maximum power dissipation for nominal condition
16.44 W (U<sub>S</sub> = 26.4 V, I<sub>L</sub>² = 72 A², P<sub>Total max</sub> = 2.04 W + 14.4 W)
Rated surge voltage/insulation
See data sheet, section “Insulation coordination”.
Rated control circuit supply voltage U<sub>S</sub>
Rated control supply current I<sub>S</sub>
typ. 70 mA (at U<sub>S</sub>)
Power consumption at U<sub>S</sub>
Inrush current
< 100 mA (typ. with U<sub>S</sub> at S12)
< 3.5 A (typ. with U<sub>S</sub>, Δt = 3 ms)
< 6 mA (typ. with U<sub>S</sub>)
> -100 mA (typ. with U<sub>S</sub> at S22)
max. 6 A
min. 10 mA
Filter time
5 ms (in the event of voltage dips at U<sub>s</sub>)
No test pulses permitted
Protective circuit
Serial protection against polarity reversal
Suppressor diode
Description of the input
non-safety-related
safety-related
Input voltage range "0" signal
Input voltage range "1" signal
20.4 V ... 26.4 V
20.4 V ... 26.4 V (S12)
Input current range "0" signal
Max. permissible overall conductor resistance
Current consumption
-38 mA (typ. with U<sub>S</sub> at S22)
1 mA (typ. with U<sub>S</sub>)
38 mA (typ. with U<sub>S</sub> at S12)
Output description
2 N/C contacts parallel, non-safety-related, floating
2 N/O contacts in series, safety-related, floating
Contact switching type
1 signaling current path
2 enabling current paths
Switching voltage
max. 250 V AC/DC
min. 10 V AC/DC
Switching capacity
1.5 A (AC15)
2 A (DC13)
5 A (AC15)
6 A (DC13)
Limiting continuous current
Sq. Total current
36 A<sup>2</sup> (see to derating)
72 A<sup>2</sup> (observe derating)
Output fuse
10 A gL/gG (High demand)
4 A gL/gG (Low demand)
6 A (gL/gG)
Conductor cross-section rigid
Conductor cross-section flexible