Typ. starting time with Us
60 ms (At Us/on demand via A1)
Application
Emergency stop
Process technology
Safety door
Mechanical service life
10<sup>7</sup> cycles
approx. 10<sup>7</sup> cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typical response time
60 ms (For U<sub>s </sub>autostart)
typ. 60 ms (For U<sub>s </sub>manual, monitored start)
Typ. starting time with U<sub>s</sub>
60 ms (At Us/on demand via A1)
Typical release time
typ. 20 ms (At Us/on demand via A1)
Recovery time
≥ 1 s (following demand of the safety function)
Maximum power dissipation for nominal condition
16.12 W (At U<sub>S</sub> = 26.4 V, I<sub>L</sub>² = 72 A², P<sub>Total max</sub>= 1.72 W + 14.4 W)
Rated surge voltage/insulation
See data sheet, section “Insulation coordination”.
Description of the input
non-safety-related
safety-related
Input voltage range "1" signal
Inrush current
< 14 mA (typ. with U<sub>S</sub> at Y2, Δt - 10 ms)
max. 1 A (typ. with U<sub>S</sub>, Δt = < 10 ms)
max. 6 A
min. 10 mA
Filter time
max. 3 ms (Test pulse width of low test pulses)
min. 200 ms (Test pulse rate for low test pulse)
No brightness test pulses / high test pulses permitted.
No test pulses permitted
Max. permissible overall conductor resistance
Current consumption
0 mA (typ. with U<sub>S</sub> at Y2)
65 mA (typ. with U<sub>S</sub>)
Output description
2 N/C contacts parallel, non-safety-related, floating
2 N/O contacts each in series, safety-related, floating
Contact switching type
1 signaling current path
2 enabling current paths
Switching voltage
max. 250 V AC/DC
min. 10 V
min. 10 V AC/DC
Switching capacity
1.5 A (AC15)
2 A (DC13)
5 A (AC15)
5 A (DC13)
Limiting continuous current
6 A
6 A (Observe derating and load limit curve)
Sq. Total current
36 A<sup>2</sup> (observe derating)
72 A<sup>2</sup> (observe derating)
Output fuse
10 A gL/gG
4 A gL/gG (for low-demand applications)
6 A gL/gG
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section, flexible, with ferrule, with plastic sleeve
0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section, flexible, with ferrule, without plastic sleeve
0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG
Operating voltage display