Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
did you mean:
Show more results in separate page
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
PSR-SPP- 24DC/ESD/5X1/1X2/T10S Safety relays
N
0%
2981509

PSR-SPP- 24DC/ESD/5X1/1X2/T10S Safety relays

Manufactured by
Brand PHOENIX CONTACT
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with a fixed dropout delay of 10 s, pluggable Push-in terminal block
4017918981105
No suppliers found
Product recommended retail price (RRP) is
000
47060 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
0
pcs.
Properties
Description
Dimensions
Files
Codes
Note on application
Only for industrial use
Rated control circuit supply voltage US
24 V DC -15 % / +10 %
Power consumption at US
typ. 3.6 W
Product type
Safety relays
Product family
PSRclassic
Rated control supply current IS
typ. 150 mA
Application
Emergency stop
Light grid
Safety door
Typ. starting time with Us
< 600 ms (when controlled via A1)
Control
1 and 2 channel
Mechanical service life
10x 10<sup>6</sup> cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Overvoltage category
III
Degree of pollution
2
Maximum power dissipation for nominal condition
3.6 W
Nominal operating mode
100% operating factor
Rated insulation voltage
250 V AC
Rated surge voltage/insulation
Rated control circuit supply voltage U&lt;sub&gt;S&lt;/sub&gt;
20.4 V DC ... 26.4 V DC
24 V DC -15 % / +10 %
Power consumption at U&lt;sub&gt;S&lt;/sub&gt;
typ. 3.6 W
Rated control supply current I&lt;sub&gt;S&lt;/sub&gt;
typ. 150 mA
Inrush current
< 150 mA (with U<sub>s</sub>/I<sub>x </sub>to S12)
< 40 mA (with U<sub>s</sub>/I<sub>x </sub>to S10)
> -60 mA (with U<sub>s</sub>/I<sub>x </sub>to S22)
200 mA (at U<sub>S</sub>)
Current consumption
< 40 mA (with U<sub>s</sub>/I<sub>x </sub>to S10)
> -40 mA (with U<sub>s</sub>/I<sub>x </sub>to S22)
0 mA (with U<sub>s</sub>/I<sub>x </sub>to S34)
Voltage at input/start and feedback circuit
24 V DC -15 % / +10 %
Filter time
1 ms (at A1 in the event of voltage dips at U<sub>s</sub>)
7.5 ms (at S10, S12; test pulse rate)
max. 1.5 ms (at S10, S12; test pulse width)
Test pulse rate = 5 x Test pulse width
Typical response time
< 600 ms (automatic start)
< 70 ms (manual start)
Typ. starting time with U&lt;sub&gt;s&lt;/sub&gt;
< 600 ms (when controlled via A1)
Typical release time
< 20 ms (when controlled via A1)
< 20 ms (when controlled via S11/S12 and S21/S22)
Concurrence
Recovery time
< 1 s
Delay time
K3(t), K4(t) fixed depending on model
Maximum switching frequency
0.5 Hz
Protective circuit
Surge protection; Suppressor diode
Max. permissible overall conductor resistance
approx. 11 Ω (Input and start circuits at U<sub>S</sub>)
Operating voltage display
1 x LED (green)
Status display
4 x LED (green)
Contact switching type
1 signaling current path
5 enabling current paths
Contact material
AgSnO<sub>2</sub>
Maximum switching voltage
250 V AC/DC (Observe the load curve)
Minimum switching voltage
5 V AC/DC
Limiting continuous current
6 A (N/C contact)
6 A (N/O contact, pay attention to the derating)
Maximum inrush current
20 A (Δt  100 ms, undelayed contacts)
8 A (delayed contacts)
Inrush current, minimum
10 mA
Sq. Total current
55 A<sup>2</sup> (observe derating)
Interrupting rating (ohmic load) max.
110 W (110 V DC, τ = 0 ms, delayed contacts: 77 W)
144 W (24 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms, delayed contacts: 2000 VA)
288 W (48 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
Maximum interrupting rating (inductive load)
42 W (110 V DC, τ = 40 ms, delayed contacts: 35 W)
42 W (220 V DC, τ = 40 ms, delayed contacts: 33 W)
42 W (24 V DC, τ = 40 ms, delayed contacts: 48 W)
42 W (48 V DC, τ = 40 ms, delayed contacts: 40 W)
Switching power min.
50 mW
Switching capacity (360/h cycles)
4 A (230 V AC)
4 A (24 V DC)
Switching capacity (3600/h cycles)
2.5 A (24 V (DC13))
3 A (230 V (AC15))
Output fuse
10 A gL/gG (N/O contact)
6 A gL/gG (N/C contact)
pluggable
yes
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27371819
ECLASS-15.0
27371819
ETIM 10.0
EC001449
UNSPSC 21.0
39122200
GTIN
4017918981105
ECLASS-15.0 ASSET
27250101
Item accessories
0%
CRIMPFOX 6
N
1212034 CRIMPFOX 6
13010 0 €
only
available
100+
inquiry
0
2026-08-31
pcs.
No related items found