Typ. starting time with Us
typ. 15 ms (with U<sub>s</sub> when controlled via A1)
Rated control circuit supply voltage US
Application
High demand
Low demand
Safe switch off
Rated control supply current IS
Mechanical service life
10x 10<sup>6</sup> cycles
Relay type
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Typ. starting time with U<sub>s</sub>
typ. 15 ms (with U<sub>s</sub> when controlled via A1)
Typical release time
typ. 15 ms (with U<sub>s</sub> when controlled via A1)
Maximum power dissipation for nominal condition
6.11 W (at U<sub>B</sub> = 26.4 V DC, U<sub>S</sub> = 24 V, I<sub>S</sub> = 45 mA, n = 1, I<sub>L</sub>² = 48 A², R<sub>contact</sub> = 0.1 )
Rated surge voltage/insulation
4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)
Rated control circuit supply voltage U<sub>S</sub>
Rated control supply current I<sub>S</sub>
Power consumption at U<sub>S</sub>
Filter time
1 ms (at A1-A2; test pulse width)
1 s (at A1-A2; test pulse rate)
Protective circuit
Suppressor diode
Surge protection
Contact switching type
3 enabling current paths
3 signaling current paths
Switching voltage
max. 250 V AC/DC
min. 5 V AC/DC
Switching capacity
5 A (24 V (DC13))
5 A (250 V (AC15))
5 A (AC15, 250 V)
5 A (DC13, 24 V)
Limiting continuous current
Interrupting rating (ohmic load) max.
Maximum interrupting rating (inductive load)
33 W (N/O contact, 220 V DC, τ = 40 ms)
35 W (N/O contact, 110 V DC, τ = 40 ms)
36 W (N/O contact, 60 V DC, τ = 40 ms)
40 W (N/O contact, 48 V DC, τ = 40 ms)
48 W (N/O contact, 24 V DC, τ = 40 ms)
Output fuse
10 A gL/gG NEOZED
4 A gL/gG NEOZED (Low demand)
6 A gL/gG NEOZED
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section, flexible, with ferrule, with plastic sleeve
0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section, flexible, with ferrule, without plastic sleeve
0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG
Operating voltage display