Order information:
Fuse-link not supplied as standard
Maximum power dissipation for nominal condition
LED voltage range
12 V DC ... 30 V DC (LED red)
Number of connections per level
Internal cylindrical gage
Connection in acc. with standard
Conductor cross-section rigid
0.5 mm² ... 10 mm²
1 mm² ... 10 mm²
Cross section AWG
20 ... 8 (converted acc. to IEC)
Conductor cross-section flexible
Conductor cross-section, flexible [AWG]
20 ... 8 (converted acc. to IEC)
Conductor cross-section flexible ultrasound-compressed
Conductor cross-section, flexible [AWG] ultrasound-compressed
22 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.5 mm² ... 6 mm²
1 mm² ... 6 mm²
Flexible conductor cross-section (ferrule with plastic sleeve)
0.5 mm² ... 6 mm²
1 mm² ... 6 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 2.5 mm² When using TWIN ferrules, we recommend a minimum ferrule length of 13 mm.
Nominal current
25 A (with 4 mm² conductor cross-section)
Maximum load current
30 A (In separate arrangement with 4 mm² conductor cross-section)
Flammability rating according to UL 94
Insulating material group
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)
Ambient temperature (actuation)
Permissible humidity (operation)
Permissible humidity (storage/transport)