Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
Rated current
≤ 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
0.5 A
0.5 A (Contacts)
1 A
1 A (at 60 °C)
1 A (At T = 50°C)
1 A (Signal contacts at T = 98°C)
1.5 A
1.5 A (at 20 °C)
1.5 A (IEC 60603-7)
1.75 A
1.8 A
10 A
10 A (control contacts)
10 A (Control insert)
10 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
100 A
100 A (power contacts)
100 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
101 A
107.5 A
109 A
12 A
120 A
120 A (with 25 mm² conductor cross-section, in accordance with IEC 61984)
120 A (with AWG 4, in accordance with UL 4128)
123 A
125 A
13.5 A
133 A
134 A
14 A (Power, in accordance with DIN VDE 0298-4 Tab. 11/5)
14.1 A (With 2.5 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
14.5 A
14.5 A (1.5 mm²)
15 A
15.5 A
150 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
150 A (With AWG 2, in accordance with UL 4128)
150 A (with AWG 2/0, in accordance with UL 4128)
16 A
16 A (4 mm²)
16 A (at 20 °C)
16 A (control contacts)
16 A (in accordance with IEC 61984 at 25 °C ambient temperature)
16 A (in accordance with IEC 61984)
16 A (power contacts)
16 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
16 A (When plugged in)
16.5 A
16.5 A (1.5 mm²)
160 A
160 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
17 A
17.3 A (With 4 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
17.5 - 24 A
17.5 A
17.5 A (in accordance with IEC 61984 at ambient temperature: 30°C)
18 A
18 A (Signal, according to DIN VDE 0298-4 tab. 11/5)
18.5 A
18.5 A (2.5 mm²)
180 A
187 A
19 A
19 A (2.5 mm²)
19 A (with AWG 14, in accordance with UL 2237)
19.5 A
2 A
20 A
20 A (2.5 mm²)
20 A (4 mm²)
20 A (in accordance with IEC 61535)
20 A (observe derating)
20 A (power contacts)
20 A (Power insert)
20 A (See also derating-diagram)
20 A (Unplugged and during plugging)
20 A (When plugged in)
20 A (With 2.5 mm² conductor cross-section in accordance with IEC 61535)
20 A (With 2.5 mm²/AWG 14, in accordance with UL 2238)
20 A (ΔT 45 K)
20.5 A
20.5 A (2.5 mm²)
200 A
200 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
200 A (with 50 mm² conductor cross-section, in accordance with IEC 61984)
200 A (With AWG 1/0, in accordance with UL 4128)
21 A
21.4 A (With 6 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
215 A
216 A
22 A
22.5 A
22.5 A (2.5 mm²)
23 A
23 A (4 mm²)
24 A
24 A (4 mm²)
24 A (in accordance with IEC 61984)
24 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
24 A (with AWG 12, in accordance with UL 2237)
24 A (with AWG 14, in accordance with UL 2237)
25 A
25 A (in accordance with IEC 61535)
25 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
25 A (With 4 mm² conductor cross-section in accordance with IEC 61535)
25 A (with 6 mm² conductor cross-section)
25.5 A
250 A (with 70 mm² conductor cross-section, in accordance with IEC 61984)
250 A (with AWG 2/0, in accordance with UL 4128)
256 A
26 A
26 A (4 mm²)
26 A (Power, in accordance with DIN VDE 0298-4 Tab. 11/5)
26.5 A
27 A
27 A (4 mm²)
27.5 A
28 A
28 A (4 mm²)
28 A (with AWG 10, in accordance with UL 2237)
28.5 A
29 A
29 A (4 mm²)
29 A (with AWG 12, in accordance with UL 2237)
29.5 A
3 A
3 A (at 20 °C)
3 A (Power contacts at T = 90°C)
3.6 A (Data, according to DIN VDE 0298-4 tab. 11/5)
30 A
30 A (in accordance with UL 6703)
300 A
300 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
300 A (with 95 mm² conductor cross-section, in accordance with IEC 61984)
300 A (with AWG 3/0, in accordance with UL 4128)
309 A
32 A
32 A (Derating in accordance with IEC 60512-5-2, 4 mm², four-conductor current feed, max. ambient temperature of 50°C)
32 A (in accordance with IEC 61535)
32 A (in accordance with IEC 61984)
32 A (observe derating)
32 A (With 4 mm² conductor cross-section in accordance with IEC 61984)
32 A (with 4 mm² conductor cross-section)
32 A (With 6 mm² conductor cross-section in accordance with IEC 61535)
32 A (with AWG 10, in accordance with UL 2237)
32 A (with AWG 12, in accordance with UL 2237)
34 A
34 A (Power, according to DIN VDE 0298-4 tab. 11/5)
35 A
35 A (4.0 mm²)
35 A (6 mm²)
35 A (in accordance with UL 6703)
35 A (power contacts)
35 A (With 6 mm² conductor cross-section in accordance with IEC 61984)
35 A (with 6 mm² conductor cross-section)
35 A (with AWG 10, in accordance with UL 2237)
35.5 A
350 A
350 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
350 A (with AWG 4/0, in accordance with UL 4128)
36 A
36.5 A
38.5 A
39 A
4 A
40 A
40 A (6 mm²)
40 A (power contacts)
40 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
400 A
400 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
400 A (With a conductor cross-section of 250 Kcmil, compliant with UL 4128 standard)
41 A
41 A (power contacts)
415 A
44 A
48.5 A
5 A
5 A (at 20 °C)
5 A (Unplugged and during plugging)
50 A
50 A (in accordance with UL 6703)
51 A
52.5 A
520 A
54 A
55 A
57 A
6 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
6.3 A
6.3 A (2.5 mm²)
6.3 A (4 mm²)
60 A
61 A
61 A (Power, according to DIN VDE 0298-4 tab. 11/5)
63 A
64.5 A
65.5 A
70 A
70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
73.5 A
76 A
76 A (with 16 mm² conductor cross-section, in accordance with IEC 61984)
8 A
8 A (Signal, according to DIN VDE 0298-4 tab. 11/5)
8 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
8 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
8.5 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
80 A
80 A (power contacts)
9 A
max. 1.5 A (USB)
max. 10 A
max. 175 mA (RJ45)
max. 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
Rated voltage
1000 (III/2.00) AC
1000 (III/2.00) DIN VDE 60664-1
1000 DIN VDE 60664-1
1000 in accordance with UL 4128
1000 V AC (III/2.00)
1000 V DC (bis 4000m ü. NN)
1000 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
1000 V DC in accordance with IEC 62852:2014/AMD1:2020
1000 V DC in accordance with UL 6703
1000V in accordance with IEC 62852:2014/AMD1:2020
1100 V
1100 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
1100 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
1500 (III/2.00)
1500 (III/2.00) in accordance with IEC 61984
1500 V
1500 V DC
1500 V DC (bis 4000m ü. NN)
1500 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
1500 V DC (III/2.00)
1500 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
1500 V DC in accordance with IEC 62852:2014/AMD1:2020
1500 V DC in accordance with UL 6703
1500 V in accordance with IEC 62852:2014/AMD1:2020
160
176 V
20 V
20 V (Contacts)
2000 V DC
2000 V DC in accordance with TÜV Rh. 2 PfG 2925/01.23
24 V DC
250
250 (III/2.00)
250 V
250 V (III/2.00)
250 VDC Minimum system voltage
275 V
277 V AC
30 V
30 V AC
352 V
40 V
400
400 V (III/2.00)
400 V (III/2.00) in accordance with IEC 61984
400 V AC (III/2.00) in accordance with IEC 61535
400 VDC (III/2.00) in accordance with IEC 61535
400 VDC (III/2.00) in accordance with IEC 61984
400 VDC (III/2.00) in accordance with UL 2238 / UL 2237
440 V
500 V
500 V AC (III/2.00) in accordance with IEC 61535/2 PfG 1915
500 V AC / DC (III/2.00) in accordance with IEC 61535, when mounted
500 V AC in accordance with IEC 61535/2 PfG 1915
500 V DC (III/2.00) in accordance with IEC 61535
500 VDC (III/2.00) in accordance with IEC 61535
550 V
60 V DC
600 V AC (III/2.00) In accordance with UL 2238
600 V AC / DC (III/2.00) In accordance with UL 2238
600 V AC / DC in accordance with UL 2237
600 V AC In accordance with UL 2238
600 VDC (III/2.00) in accordance with UL 2238 / UL 2237
690
690 V
690 V (NS 32)
690 V AC (III/2.00) in accordance with IEC 61984
690 V AC in accordance with IEC 61984
72 V DC
80 V DC
800 VDC (III/2.00) in accordance with IEC 61984
880 V
880 V (NS 35)
Dreiphasig 630 V AC (III/2.00) in accordance with IEC 61984
Rated current (10 mm²)
47 A
47 A (in accordance with IEC 62852:2014/AMD1:2020)
50 A (in accordance with IEC 62852:2014-11)
50 A (in accordance with IEC 62852:2014/AMD1:2020)
51 A (in accordance with IEC 62852:2014/AMD1:2020)
Rated current (10.0 mm²)
50 A
Rated current (16 mm²)
51 A
60 A (in accordance with IEC 62852:2014-11)
Rated current (2,5 mm²)
27 A
Rated current (2.5 mm²)
15 A
20 A
20 A (in accordance with IEC 62852:2014-11)
20 A (in accordance with IEC 62852:2014/AMD1:2020)
26 A (in accordance with IEC 62852:2014/AMD1:2020)
27 A
27 A (in accordance with IEC 62852:2014-11)
27 A (in accordance with IEC 62852:2014/AMD1:2020)
Rated current (4,0 mm²)
34 A
35 A
Rated current (4.0 mm²)
30 A
30 A (in accordance with IEC 62852:2014-11)
30 A (in accordance with IEC 62852:2014/AMD1:2020)
32 A
32 A (in accordance with IEC 62852:2014/AMD1:2020)
34 A (in accordance with IEC 62852:2014/AMD1:2020)
35 A
35 A (in accordance with IEC 62852:2014-11)
35 A (in accordance with IEC 62852:2014/AMD1:2020)
40 A
Rated current (6,0 mm²)
39 A
40 A
Brands
Montavimo medžiagos
MURRELEKTRONIK
Other brands
PHOENIX CONTACT
SIEMENS
Vendors
No vendors found
In stock
()
Show only new items
()
Rated current
≤ 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
0.5 A
()
0.5 A (Contacts)
()
1 A
()
1 A (at 60 °C)
()
1 A (At T = 50°C)
()
1 A (Signal contacts at T = 98°C)
()
1.5 A
()
1.5 A (at 20 °C)
()
1.5 A (IEC 60603-7)
()
1.75 A
()
1.8 A
()
10 A
()
10 A (control contacts)
()
10 A (Control insert)
()
10 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
100 A
()
100 A (power contacts)
()
100 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
101 A
()
107.5 A
()
109 A
()
12 A
()
120 A
()
120 A (with 25 mm² conductor cross-section, in accordance with IEC 61984)
()
120 A (with AWG 4, in accordance with UL 4128)
()
123 A
()
125 A
()
13.5 A
()
133 A
()
134 A
()
14 A (Power, in accordance with DIN VDE 0298-4 Tab. 11/5)
()
14.1 A (With 2.5 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
()
14.5 A
()
14.5 A (1.5 mm²)
()
15 A
()
15.5 A
()
150 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
()
150 A (With AWG 2, in accordance with UL 4128)
()
150 A (with AWG 2/0, in accordance with UL 4128)
()
16 A
()
16 A (4 mm²)
()
16 A (at 20 °C)
()
16 A (control contacts)
()
16 A (in accordance with IEC 61984 at 25 °C ambient temperature)
()
16 A (in accordance with IEC 61984)
()
16 A (power contacts)
()
16 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
16 A (When plugged in)
()
16.5 A
()
16.5 A (1.5 mm²)
()
160 A
()
160 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
()
17 A
()
17.3 A (With 4 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
()
17.5 - 24 A
()
17.5 A
()
17.5 A (in accordance with IEC 61984 at ambient temperature: 30°C)
()
18 A
()
18 A (Signal, according to DIN VDE 0298-4 tab. 11/5)
()
18.5 A
()
18.5 A (2.5 mm²)
()
180 A
()
187 A
()
19 A
()
19 A (2.5 mm²)
()
19 A (with AWG 14, in accordance with UL 2237)
()
19.5 A
()
2 A
()
20 A
()
20 A (2.5 mm²)
()
20 A (4 mm²)
()
20 A (in accordance with IEC 61535)
()
20 A (observe derating)
()
20 A (power contacts)
()
20 A (Power insert)
()
20 A (See also derating-diagram)
()
20 A (Unplugged and during plugging)
()
20 A (When plugged in)
()
20 A (With 2.5 mm² conductor cross-section in accordance with IEC 61535)
()
20 A (With 2.5 mm²/AWG 14, in accordance with UL 2238)
()
20 A (ΔT 45 K)
()
20.5 A
()
20.5 A (2.5 mm²)
()
200 A
()
200 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
200 A (with 50 mm² conductor cross-section, in accordance with IEC 61984)
()
200 A (With AWG 1/0, in accordance with UL 4128)
()
21 A
()
21.4 A (With 6 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
()
215 A
()
216 A
()
22 A
()
22.5 A
()
22.5 A (2.5 mm²)
()
23 A
()
23 A (4 mm²)
()
24 A
()
24 A (4 mm²)
()
24 A (in accordance with IEC 61984)
()
24 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
()
24 A (with AWG 12, in accordance with UL 2237)
()
24 A (with AWG 14, in accordance with UL 2237)
()
25 A
()
25 A (in accordance with IEC 61535)
()
25 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
()
25 A (With 4 mm² conductor cross-section in accordance with IEC 61535)
()
25 A (with 6 mm² conductor cross-section)
()
25.5 A
()
250 A (with 70 mm² conductor cross-section, in accordance with IEC 61984)
()
250 A (with AWG 2/0, in accordance with UL 4128)
()
256 A
()
26 A
()
26 A (4 mm²)
()
26 A (Power, in accordance with DIN VDE 0298-4 Tab. 11/5)
()
26.5 A
()
27 A
()
27 A (4 mm²)
()
27.5 A
()
28 A
()
28 A (4 mm²)
()
28 A (with AWG 10, in accordance with UL 2237)
()
28.5 A
()
29 A
()
29 A (4 mm²)
()
29 A (with AWG 12, in accordance with UL 2237)
()
29.5 A
()
3 A
()
3 A (at 20 °C)
()
3 A (Power contacts at T = 90°C)
()
3.6 A (Data, according to DIN VDE 0298-4 tab. 11/5)
()
30 A
()
30 A (in accordance with UL 6703)
()
300 A
()
300 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
300 A (with 95 mm² conductor cross-section, in accordance with IEC 61984)
()
300 A (with AWG 3/0, in accordance with UL 4128)
()
309 A
()
32 A
()
32 A (Derating in accordance with IEC 60512-5-2, 4 mm², four-conductor current feed, max. ambient temperature of 50°C)
()
32 A (in accordance with IEC 61535)
()
32 A (in accordance with IEC 61984)
()
32 A (observe derating)
()
32 A (With 4 mm² conductor cross-section in accordance with IEC 61984)
()
32 A (with 4 mm² conductor cross-section)
()
32 A (With 6 mm² conductor cross-section in accordance with IEC 61535)
()
32 A (with AWG 10, in accordance with UL 2237)
()
32 A (with AWG 12, in accordance with UL 2237)
()
34 A
()
34 A (Power, according to DIN VDE 0298-4 tab. 11/5)
()
35 A
()
35 A (4.0 mm²)
()
35 A (6 mm²)
()
35 A (in accordance with UL 6703)
()
35 A (power contacts)
()
35 A (With 6 mm² conductor cross-section in accordance with IEC 61984)
()
35 A (with 6 mm² conductor cross-section)
()
35 A (with AWG 10, in accordance with UL 2237)
()
35.5 A
()
350 A
()
350 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
()
350 A (with AWG 4/0, in accordance with UL 4128)
()
36 A
()
36.5 A
()
38.5 A
()
39 A
()
4 A
()
40 A
()
40 A (6 mm²)
()
40 A (power contacts)
()
40 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
400 A
()
400 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
()
400 A (With a conductor cross-section of 250 Kcmil, compliant with UL 4128 standard)
()
41 A
()
41 A (power contacts)
()
415 A
()
44 A
()
48.5 A
()
5 A
()
5 A (at 20 °C)
()
5 A (Unplugged and during plugging)
()
50 A
()
50 A (in accordance with UL 6703)
()
51 A
()
52.5 A
()
520 A
()
54 A
()
55 A
()
57 A
()
6 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
()
6.3 A
()
6.3 A (2.5 mm²)
()
6.3 A (4 mm²)
()
60 A
()
61 A
()
61 A (Power, according to DIN VDE 0298-4 tab. 11/5)
()
63 A
()
64.5 A
()
65.5 A
()
70 A
()
70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
73.5 A
()
76 A
()
76 A (with 16 mm² conductor cross-section, in accordance with IEC 61984)
()
8 A
()
8 A (Signal, according to DIN VDE 0298-4 tab. 11/5)
()
8 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
()
8 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
()
8.5 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
()
80 A
()
80 A (power contacts)
()
9 A
()
max. 1.5 A (USB)
()
max. 10 A
()
max. 175 mA (RJ45)
()
max. 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
Rated voltage
1000 (III/2.00) AC
()
1000 (III/2.00) DIN VDE 60664-1
()
1000 DIN VDE 60664-1
()
1000 in accordance with UL 4128
()
1000 V AC (III/2.00)
()
1000 V DC (bis 4000m ü. NN)
()
1000 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1000 V DC in accordance with IEC 62852:2014/AMD1:2020
()
1000 V DC in accordance with UL 6703
()
1000V in accordance with IEC 62852:2014/AMD1:2020
()
1100 V
()
1100 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1100 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1500 (III/2.00)
()
1500 (III/2.00) in accordance with IEC 61984
()
1500 V
()
1500 V DC
()
1500 V DC (bis 4000m ü. NN)
()
1500 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1500 V DC (III/2.00)
()
1500 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1500 V DC in accordance with IEC 62852:2014/AMD1:2020
()
1500 V DC in accordance with UL 6703
()
1500 V in accordance with IEC 62852:2014/AMD1:2020
()
160
()
176 V
()
20 V
()
20 V (Contacts)
()
2000 V DC
()
2000 V DC in accordance with TÜV Rh. 2 PfG 2925/01.23
()
24 V DC
()
250
()
250 (III/2.00)
()
250 V
()
250 V (III/2.00)
()
250 VDC Minimum system voltage
()
275 V
()
277 V AC
()
30 V
()
30 V AC
()
352 V
()
40 V
()
400
()
400 V (III/2.00)
()
400 V (III/2.00) in accordance with IEC 61984
()
400 V AC (III/2.00) in accordance with IEC 61535
()
400 VDC (III/2.00) in accordance with IEC 61535
()
400 VDC (III/2.00) in accordance with IEC 61984
()
400 VDC (III/2.00) in accordance with UL 2238 / UL 2237
()
440 V
()
500 V
()
500 V AC (III/2.00) in accordance with IEC 61535/2 PfG 1915
()
500 V AC / DC (III/2.00) in accordance with IEC 61535, when mounted
()
500 V AC in accordance with IEC 61535/2 PfG 1915
()
500 V DC (III/2.00) in accordance with IEC 61535
()
500 VDC (III/2.00) in accordance with IEC 61535
()
550 V
()
60 V DC
()
600 V AC (III/2.00) In accordance with UL 2238
()
600 V AC / DC (III/2.00) In accordance with UL 2238
()
600 V AC / DC in accordance with UL 2237
()
600 V AC In accordance with UL 2238
()
600 VDC (III/2.00) in accordance with UL 2238 / UL 2237
()
690
()
690 V
()
690 V (NS 32)
()
690 V AC (III/2.00) in accordance with IEC 61984
()
690 V AC in accordance with IEC 61984
()
72 V DC
()
80 V DC
()
800 VDC (III/2.00) in accordance with IEC 61984
()
880 V
()
880 V (NS 35)
()
Dreiphasig 630 V AC (III/2.00) in accordance with IEC 61984
()
Rated current (10 mm²)
47 A
()
47 A (in accordance with IEC 62852:2014/AMD1:2020)
()
50 A (in accordance with IEC 62852:2014-11)
()
50 A (in accordance with IEC 62852:2014/AMD1:2020)
()
51 A (in accordance with IEC 62852:2014/AMD1:2020)
()
Rated current (10.0 mm²)
50 A
()
Rated current (16 mm²)
51 A
()
60 A (in accordance with IEC 62852:2014-11)
()
Rated current (2,5 mm²)
27 A
()
Rated current (2.5 mm²)
15 A
()
20 A
()
20 A (in accordance with IEC 62852:2014-11)
()
20 A (in accordance with IEC 62852:2014/AMD1:2020)
()
26 A (in accordance with IEC 62852:2014/AMD1:2020)
()
27 A
()
27 A (in accordance with IEC 62852:2014-11)
()
27 A (in accordance with IEC 62852:2014/AMD1:2020)
()
Rated current (4,0 mm²)
34 A
()
35 A
()
Rated current (4.0 mm²)
30 A
()
30 A (in accordance with IEC 62852:2014-11)
()
30 A (in accordance with IEC 62852:2014/AMD1:2020)
()
32 A
()
32 A (in accordance with IEC 62852:2014/AMD1:2020)
()
34 A (in accordance with IEC 62852:2014/AMD1:2020)
()
35 A
()
35 A (in accordance with IEC 62852:2014-11)
()
35 A (in accordance with IEC 62852:2014/AMD1:2020)
()
40 A
()
Rated current (6,0 mm²)
39 A
()
40 A
()
Brands
Montavimo medžiagos
()
MURRELEKTRONIK
()
Other brands
()
PHOENIX CONTACT
()
SIEMENS
()
Vendors
No vendors found
Connectivity and Cabling ()
All prices without tax
All prices with tax
10 25 50
0%
FK-MCP 1,5/15-STF-3,5AUBD-14 Q PCB connector
N
1712472 FK-MCP 1,5/15-STF-3,5AUBD-14 Q PCB connector
1890 0 €
inquiry
only
available
100+
inquiry
0
2026-09-30
pcs.
0%
GSMKDS 3/ 3 BD:1-3 PCB terminal block
N
1712473 GSMKDS 3/ 3 BD:1-3 PCB terminal block
213 0 €
inquiry
only
available
100+
inquiry
0
2026-10-13
pcs.
0%
SMKDS 1/ 8-3,5 BD:NZ 26937-1 PCB terminal block
N
1712500 SMKDS 1/ 8-3,5 BD:NZ 26937-1 PCB terminal block
323 0 €
inquiry
only
available
100+
inquiry
0
2026-12-03
pcs.
0%
FFKDSA1/V1-5,08- 7 BS:7-1 SO PCB terminal block
N
1712501 FFKDSA1/V1-5,08- 7 BS:7-1 SO PCB terminal block
422 0 €
inquiry
only
available
100+
inquiry
0
2026-10-07
pcs.
0%
SPTA 1,5/ 8-3,81 BD:FAN-PC PCB terminal block
N
1712502 SPTA 1,5/ 8-3,81 BD:FAN-PC PCB terminal block
343 0 €
inquiry
only
available
100+
inquiry
0
2026-10-23
pcs.
0%
MKDSP 25/ 3-15,00 GY BD:U-W PCB terminal block
N
1712510 MKDSP 25/ 3-15,00 GY BD:U-W PCB terminal block
927 0 €
inquiry
only
available
100+
inquiry
0
2026-09-05
pcs.
0%
MKDSP 25/ 5-15,00 GY BD:L1 PCB terminal block
N
1712511 MKDSP 25/ 5-15,00 GY BD:L1 PCB terminal block
1540 0 €
inquiry
only
available
100+
inquiry
0
2026-10-30
pcs.
0%
MKDS 10 HV/ 2-ZB-10,16 GY BD+R PCB terminal block
N
1712512 MKDS 10 HV/ 2-ZB-10,16 GY BD+R PCB terminal block
536 0 €
inquiry
only
available
100+
inquiry
0
2026-10-15
pcs.
0%
FKC 2,5/ 3-ST-5,08BD:83,82,81SO PCB connector
N
1712513 FKC 2,5/ 3-ST-5,08BD:83,82,81SO PCB connector
211 0 €
inquiry
only
available
100+
inquiry
0
2026-09-23
pcs.
0%
MCV 1,5/ 6-G-3,5 BD:X12 PCB header
N
1712522 MCV 1,5/ 6-G-3,5 BD:X12 PCB header
173 0 €
inquiry
only
available
100+
inquiry
0
2026-09-23
pcs.
0%
FKC 2,5/ 5-ST-5,08 CP1 BD:NZ PCB connector
N
1712526 FKC 2,5/ 5-ST-5,08 CP1 BD:NZ PCB connector
431 0 €
inquiry
only
available
100+
inquiry
0
2026-09-23
pcs.
0%
MCVW 1,5/ 4-ST-3,5 BD:X14/1-4 PCB connector
N
1712527 MCVW 1,5/ 4-ST-3,5 BD:X14/1-4 PCB connector
305 0 €
inquiry
only
available
100+
inquiry
0
2026-10-08
pcs.
0%
MCVW 1,5/ 6-ST-3,5 BD:X12/1-6 PCB connector
N
1712528 MCVW 1,5/ 6-ST-3,5 BD:X12/1-6 PCB connector
452 0 €
inquiry
only
available
100+
inquiry
0
2026-10-08
pcs.
0%
ZFKDSA 1,5C-5,0- 4 GY PCB terminal block
N
1712529 ZFKDSA 1,5C-5,0- 4 GY PCB terminal block
112 0 €
inquiry
only
available
100+
inquiry
0
2026-10-28
pcs.
0%
MKDS 5/ 4-9,5 Z1L TS BK PCB terminal block
N
1712530 MKDS 5/ 4-9,5 Z1L TS BK PCB terminal block
284 0 €
inquiry
only
available
100+
inquiry
0
2026-09-22
pcs.
0%
FKC 2,5/ 6-ST-5,08-RF BDMC-1SO PCB connector
N
1712538 FKC 2,5/ 6-ST-5,08-RF BDMC-1SO PCB connector
593 0 €
inquiry
only
available
100+
inquiry
0
2026-09-30
pcs.
0%
FKC 2,5/ 6-ST-5,08 BD:NZN-D PCB connector
N
1712539 FKC 2,5/ 6-ST-5,08 BD:NZN-D PCB connector
418 0 €
inquiry
only
available
100+
inquiry
0
2026-09-23
pcs.
0%
ICV 2,5/ 8-GF-5,08 BG PCB header
N
1712542 ICV 2,5/ 8-GF-5,08 BG PCB header
512 0 €
inquiry
only
available
100+
inquiry
0
2026-09-23
pcs.
0%
SPT 16/ 1-V-10,0 BU PCB terminal block
N
1712550 SPT 16/ 1-V-10,0 BU PCB terminal block
236 0 €
inquiry
only
available
100+
inquiry
0
2026-11-27
pcs.
0%
SPT 16/ 1-V-10,0 VT PCB terminal block
N
1712551 SPT 16/ 1-V-10,0 VT PCB terminal block
236 0 €
inquiry
only
available
100+
inquiry
0
2026-09-05
pcs.
0%
SMKDS 2,5/ 3-5,08 GY PCB terminal block
N
1712560 SMKDS 2,5/ 3-5,08 GY PCB terminal block
160 0 €
inquiry
only
available
100+
inquiry
0
2026-09-30
pcs.
0%
MSTBA 2,5/ 3-G-5,08 OG PCB header
N
1712568 MSTBA 2,5/ 3-G-5,08 OG PCB header
067 0 €
inquiry
only
available
100+
inquiry
0
2026-09-05
pcs.
0%
PCV 4/ 4-GF-7,62 BG PCB header
N
1712584 PCV 4/ 4-GF-7,62 BG PCB header
429 0 €
inquiry
only
available
100+
inquiry
0
2026-11-11
pcs.
0%
MC 1,5/ 2-ST-5,08 BD:1,2 PCB connector
N
1712597 MC 1,5/ 2-ST-5,08 BD:1,2 PCB connector
140 0 €
inquiry
only
available
100+
inquiry
0
2026-10-13
pcs.
0%
MKDS 3/10 PCB terminal block
N
1712601 MKDS 3/10 PCB terminal block
443 0 €
inquiry
only
available
100+
inquiry
0
2026-09-23
pcs.