Your Language:
English (en)
Debug
Administrator
Testing
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
Rated current
max. 10 A
max. 1.5 A (USB)
max. 175 mA (RJ45)
≤ 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
max. 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
0.5 A
1 A (Signal contacts at T = 98°C)
1 A (At T = 50°C)
1 A
1 A (at 60 °C)
1.5 A
1.75 A
2 A
3 A (Power contacts at T = 90°C)
3 A (at 20 °C)
4 A
5 A
5 A (Unplugged and during plugging)
6 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
8 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
8 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
8 A
8.5 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
9 A
10 A
10 A (Control insert)
10 A (control contacts)
10 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
12 A
14.1 A (With 2.5 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
15 A
16 A (power contacts)
16 A (When plugged in)
16 A (control contacts)
16 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
16 A (in accordance with IEC 61984 at 25 °C ambient temperature)
16 A (in accordance with IEC 61984)
16 A (at 20 °C)
16 A
17.3 A (With 4 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
17.5 A
17.5 A (in accordance with IEC 61984 at ambient temperature: 30°C)
19 A (with AWG 14, in accordance with UL 2237)
20 A (observe derating)
20 A (power contacts)
20 A (Power insert)
20 A (Unplugged and during plugging)
20 A (When plugged in)
20 A (See also derating-diagram)
20 A
20 A (in accordance with IEC 61535)
20 A (With 2.5 mm²/AWG 14, in accordance with UL 2238)
20 A (With 2.5 mm² conductor cross-section in accordance with IEC 61535)
21.4 A (With 6 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
24 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
24 A (with AWG 12, in accordance with UL 2237)
24 A
24 A (in accordance with IEC 61984)
24 A (with AWG 14, in accordance with UL 2237)
25 A
25 A (With 4 mm² conductor cross-section in accordance with IEC 61535)
25 A (with 6 mm² conductor cross-section)
25 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
25 A (in accordance with IEC 61535)
28 A (with AWG 10, in accordance with UL 2237)
29 A (with AWG 12, in accordance with UL 2237)
30 A (in accordance with UL 6703)
30 A
32 A (in accordance with IEC 61535)
32 A (Derating in accordance with IEC 60512-5-2, 4 mm², four-conductor current feed, max. ambient temperature of 50°C)
32 A (in accordance with IEC 61984)
32 A (observe derating)
32 A (with AWG 10, in accordance with UL 2237)
32 A (With 6 mm² conductor cross-section in accordance with IEC 61535)
32 A (With 4 mm² conductor cross-section in accordance with IEC 61984)
32 A (with AWG 12, in accordance with UL 2237)
32 A (with 4 mm² conductor cross-section)
35 A (in accordance with UL 6703)
35 A (with 6 mm² conductor cross-section)
35 A (4.0 mm²)
35 A
35 A (With 6 mm² conductor cross-section in accordance with IEC 61984)
35 A (with AWG 10, in accordance with UL 2237)
35 A (power contacts)
40 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
40 A
40 A (power contacts)
41 A (power contacts)
50 A (in accordance with UL 6703)
60 A
63 A
70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
70 A
76 A (with 16 mm² conductor cross-section, in accordance with IEC 61984)
76 A
80 A
80 A (power contacts)
100 A (power contacts)
100 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
100 A
120 A (with 25 mm² conductor cross-section, in accordance with IEC 61984)
120 A
120 A (with AWG 4, in accordance with UL 4128)
150 A (with AWG 2/0, in accordance with UL 4128)
150 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
150 A (With AWG 2, in accordance with UL 4128)
160 A
160 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
200 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
200 A (with 50 mm² conductor cross-section, in accordance with IEC 61984)
200 A
200 A (With AWG 1/0, in accordance with UL 4128)
250 A (with AWG 2/0, in accordance with UL 4128)
250 A (with 70 mm² conductor cross-section, in accordance with IEC 61984)
300 A (with 95 mm² conductor cross-section, in accordance with IEC 61984)
300 A
300 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
300 A (with AWG 3/0, in accordance with UL 4128)
350 A (with AWG 4/0, in accordance with UL 4128)
350 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
350 A
400 A (With a conductor cross-section of 250 Kcmil, compliant with UL 4128 standard)
400 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
400 A
Rated voltage
500 V DC (III/2.00) in accordance with IEC 61535
400 V (III/2.00) in accordance with IEC 61984
400 V AC (III/2.00) in accordance with IEC 61535
690 V AC (III/2.00) in accordance with IEC 61984
1000 V DC in accordance with IEC 62852:2014/AMD1:2020
1500 V DC (III/2.00)
1000 V AC (III/2.00)
1500 (III/2.00)
500 V AC (III/2.00) in accordance with IEC 61535/2 PfG 1915
600 V AC (III/2.00) In accordance with UL 2238
600 V AC In accordance with UL 2238
690 V AC in accordance with IEC 61984
1000 V DC (bis 4000m ü. NN)
1000 (III/2.00) AC
500 V AC / DC (III/2.00) in accordance with IEC 61535, when mounted
1500 V DC (bis 4000m ü. NN)
250 VDC Minimum system voltage
500 V AC in accordance with IEC 61535/2 PfG 1915
1500 V DC in accordance with IEC 62852:2014/AMD1:2020
160
250 (III/2.00)
250
800 VDC (III/2.00) in accordance with IEC 61984
500 VDC (III/2.00) in accordance with IEC 61535
600 VDC (III/2.00) in accordance with UL 2238 / UL 2237
1000 in accordance with UL 4128
1500 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
1500 (III/2.00) in accordance with IEC 61984
2000 V DC in accordance with TÜV Rh. 2 PfG 2925/01.23
400
Dreiphasig 630 V AC (III/2.00) in accordance with IEC 61984
2000 V DC
400 V (III/2.00)
1500 V DC in accordance with UL 6703
600 V AC / DC in accordance with UL 2237
1500 V DC
690
1500 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
600 V AC / DC (III/2.00) In accordance with UL 2238
400 VDC (III/2.00) in accordance with UL 2238 / UL 2237
400 VDC (III/2.00) in accordance with IEC 61535
400 VDC (III/2.00) in accordance with IEC 61984
1100 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
1000 DIN VDE 60664-1
1000 V DC in accordance with UL 6703
1100 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
1000 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
1500 V
1000 (III/2.00) DIN VDE 60664-1
1500 V in accordance with IEC 62852:2014/AMD1:2020
250 V (III/2.00)
1000V in accordance with IEC 62852:2014/AMD1:2020
Rated current (10 mm²)
47 A
47 A (in accordance with IEC 62852:2014/AMD1:2020)
50 A (in accordance with IEC 62852:2014-11)
50 A (in accordance with IEC 62852:2014/AMD1:2020)
51 A (in accordance with IEC 62852:2014/AMD1:2020)
Rated current (10.0 mm²)
50 A
Rated current (16 mm²)
51 A
60 A (in accordance with IEC 62852:2014-11)
Rated current (2,5 mm²)
27 A
Rated current (2.5 mm²)
15 A
20 A
20 A (in accordance with IEC 62852:2014-11)
20 A (in accordance with IEC 62852:2014/AMD1:2020)
26 A (in accordance with IEC 62852:2014/AMD1:2020)
27 A
27 A (in accordance with IEC 62852:2014-11)
27 A (in accordance with IEC 62852:2014/AMD1:2020)
Rated current (4,0 mm²)
34 A
35 A
Rated current (4.0 mm²)
30 A
30 A (in accordance with IEC 62852:2014-11)
30 A (in accordance with IEC 62852:2014/AMD1:2020)
32 A
32 A (in accordance with IEC 62852:2014/AMD1:2020)
34 A (in accordance with IEC 62852:2014/AMD1:2020)
35 A
35 A (in accordance with IEC 62852:2014-11)
35 A (in accordance with IEC 62852:2014/AMD1:2020)
40 A
Rated current (6,0 mm²)
39 A
40 A
Brands
MURRELEKTRONIK
Other brands
PHOENIX CONTACT
SIEMENS
Vendors
No vendors found
In stock
()
Show only new items
()
Rated current
max. 10 A
()
max. 1.5 A (USB)
()
max. 175 mA (RJ45)
()
≤ 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
max. 70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
0.5 A
()
1 A (Signal contacts at T = 98°C)
()
1 A (At T = 50°C)
()
1 A
()
1 A (at 60 °C)
()
1.5 A
()
1.75 A
()
2 A
()
3 A (Power contacts at T = 90°C)
()
3 A (at 20 °C)
()
4 A
()
5 A
()
5 A (Unplugged and during plugging)
()
6 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
()
8 A (with 0.75 mm² conductor cross-section in accordance with IEC 61984)
()
8 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
()
8 A
()
8.5 A (with 1 mm² conductor cross-section in accordance with IEC 61984)
()
9 A
()
10 A
()
10 A (Control insert)
()
10 A (control contacts)
()
10 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
12 A
()
14.1 A (With 2.5 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
()
15 A
()
16 A (power contacts)
()
16 A (When plugged in)
()
16 A (control contacts)
()
16 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
16 A (in accordance with IEC 61984 at 25 °C ambient temperature)
()
16 A (in accordance with IEC 61984)
()
16 A (at 20 °C)
()
16 A
()
17.3 A (With 4 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
()
17.5 A
()
17.5 A (in accordance with IEC 61984 at ambient temperature: 30°C)
()
19 A (with AWG 14, in accordance with UL 2237)
()
20 A (observe derating)
()
20 A (power contacts)
()
20 A (Power insert)
()
20 A (Unplugged and during plugging)
()
20 A (When plugged in)
()
20 A (See also derating-diagram)
()
20 A
()
20 A (in accordance with IEC 61535)
()
20 A (With 2.5 mm²/AWG 14, in accordance with UL 2238)
()
20 A (With 2.5 mm² conductor cross-section in accordance with IEC 61535)
()
21.4 A (With 6 mm² conductor cross-section and 85 °C in accordance with 2 PfG 1915)
()
24 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
()
24 A (with AWG 12, in accordance with UL 2237)
()
24 A
()
24 A (in accordance with IEC 61984)
()
24 A (with AWG 14, in accordance with UL 2237)
()
25 A
()
25 A (With 4 mm² conductor cross-section in accordance with IEC 61535)
()
25 A (with 6 mm² conductor cross-section)
()
25 A (With 2.5 mm² conductor cross-section in accordance with IEC 61984)
()
25 A (in accordance with IEC 61535)
()
28 A (with AWG 10, in accordance with UL 2237)
()
29 A (with AWG 12, in accordance with UL 2237)
()
30 A (in accordance with UL 6703)
()
30 A
()
32 A (in accordance with IEC 61535)
()
32 A (Derating in accordance with IEC 60512-5-2, 4 mm², four-conductor current feed, max. ambient temperature of 50°C)
()
32 A (in accordance with IEC 61984)
()
32 A (observe derating)
()
32 A (with AWG 10, in accordance with UL 2237)
()
32 A (With 6 mm² conductor cross-section in accordance with IEC 61535)
()
32 A (With 4 mm² conductor cross-section in accordance with IEC 61984)
()
32 A (with AWG 12, in accordance with UL 2237)
()
32 A (with 4 mm² conductor cross-section)
()
35 A (in accordance with UL 6703)
()
35 A (with 6 mm² conductor cross-section)
()
35 A (4.0 mm²)
()
35 A
()
35 A (With 6 mm² conductor cross-section in accordance with IEC 61984)
()
35 A (with AWG 10, in accordance with UL 2237)
()
35 A (power contacts)
()
40 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
40 A
()
40 A (power contacts)
()
41 A (power contacts)
()
50 A (in accordance with UL 6703)
()
60 A
()
63 A
()
70 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
70 A
()
76 A (with 16 mm² conductor cross-section, in accordance with IEC 61984)
()
76 A
()
80 A
()
80 A (power contacts)
()
100 A (power contacts)
()
100 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
100 A
()
120 A (with 25 mm² conductor cross-section, in accordance with IEC 61984)
()
120 A
()
120 A (with AWG 4, in accordance with UL 4128)
()
150 A (with AWG 2/0, in accordance with UL 4128)
()
150 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
()
150 A (With AWG 2, in accordance with UL 4128)
()
160 A
()
160 A (with 35 mm² conductor cross-section, in accordance with IEC 61984)
()
200 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
200 A (with 50 mm² conductor cross-section, in accordance with IEC 61984)
()
200 A
()
200 A (With AWG 1/0, in accordance with UL 4128)
()
250 A (with AWG 2/0, in accordance with UL 4128)
()
250 A (with 70 mm² conductor cross-section, in accordance with IEC 61984)
()
300 A (with 95 mm² conductor cross-section, in accordance with IEC 61984)
()
300 A
()
300 A (Take into account the derating of the contact insert used. The rated current corresponds to the maximum possible connection cross-section.)
()
300 A (with AWG 3/0, in accordance with UL 4128)
()
350 A (with AWG 4/0, in accordance with UL 4128)
()
350 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
()
350 A
()
400 A (With a conductor cross-section of 250 Kcmil, compliant with UL 4128 standard)
()
400 A (with 120 mm² conductor cross-section, in accordance with IEC 61984)
()
400 A
()
Rated voltage
500 V DC (III/2.00) in accordance with IEC 61535
()
400 V (III/2.00) in accordance with IEC 61984
()
400 V AC (III/2.00) in accordance with IEC 61535
()
690 V AC (III/2.00) in accordance with IEC 61984
()
1000 V DC in accordance with IEC 62852:2014/AMD1:2020
()
1500 V DC (III/2.00)
()
1000 V AC (III/2.00)
()
1500 (III/2.00)
()
500 V AC (III/2.00) in accordance with IEC 61535/2 PfG 1915
()
600 V AC (III/2.00) In accordance with UL 2238
()
600 V AC In accordance with UL 2238
()
690 V AC in accordance with IEC 61984
()
1000 V DC (bis 4000m ü. NN)
()
1000 (III/2.00) AC
()
500 V AC / DC (III/2.00) in accordance with IEC 61535, when mounted
()
1500 V DC (bis 4000m ü. NN)
()
250 VDC Minimum system voltage
()
500 V AC in accordance with IEC 61535/2 PfG 1915
()
1500 V DC in accordance with IEC 62852:2014/AMD1:2020
()
160
()
250 (III/2.00)
()
250
()
800 VDC (III/2.00) in accordance with IEC 61984
()
500 VDC (III/2.00) in accordance with IEC 61535
()
600 VDC (III/2.00) in accordance with UL 2238 / UL 2237
()
1000 in accordance with UL 4128
()
1500 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1500 (III/2.00) in accordance with IEC 61984
()
2000 V DC in accordance with TÜV Rh. 2 PfG 2925/01.23
()
400
()
Dreiphasig 630 V AC (III/2.00) in accordance with IEC 61984
()
2000 V DC
()
400 V (III/2.00)
()
1500 V DC in accordance with UL 6703
()
600 V AC / DC in accordance with UL 2237
()
1500 V DC
()
690
()
1500 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
600 V AC / DC (III/2.00) In accordance with UL 2238
()
400 VDC (III/2.00) in accordance with UL 2238 / UL 2237
()
400 VDC (III/2.00) in accordance with IEC 61535
()
400 VDC (III/2.00) in accordance with IEC 61984
()
1100 V DC (III/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1000 DIN VDE 60664-1
()
1000 V DC in accordance with UL 6703
()
1100 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1000 V DC (II/2.00) in accordance with IEC 62852:2014/AMD1:2020
()
1500 V
()
1000 (III/2.00) DIN VDE 60664-1
()
1500 V in accordance with IEC 62852:2014/AMD1:2020
()
250 V (III/2.00)
()
1000V in accordance with IEC 62852:2014/AMD1:2020
()
Rated current (10 mm²)
47 A
()
47 A (in accordance with IEC 62852:2014/AMD1:2020)
()
50 A (in accordance with IEC 62852:2014-11)
()
50 A (in accordance with IEC 62852:2014/AMD1:2020)
()
51 A (in accordance with IEC 62852:2014/AMD1:2020)
()
Rated current (10.0 mm²)
50 A
()
Rated current (16 mm²)
51 A
()
60 A (in accordance with IEC 62852:2014-11)
()
Rated current (2,5 mm²)
27 A
()
Rated current (2.5 mm²)
15 A
()
20 A
()
20 A (in accordance with IEC 62852:2014-11)
()
20 A (in accordance with IEC 62852:2014/AMD1:2020)
()
26 A (in accordance with IEC 62852:2014/AMD1:2020)
()
27 A
()
27 A (in accordance with IEC 62852:2014-11)
()
27 A (in accordance with IEC 62852:2014/AMD1:2020)
()
Rated current (4,0 mm²)
34 A
()
35 A
()
Rated current (4.0 mm²)
30 A
()
30 A (in accordance with IEC 62852:2014-11)
()
30 A (in accordance with IEC 62852:2014/AMD1:2020)
()
32 A
()
32 A (in accordance with IEC 62852:2014/AMD1:2020)
()
34 A (in accordance with IEC 62852:2014/AMD1:2020)
()
35 A
()
35 A (in accordance with IEC 62852:2014-11)
()
35 A (in accordance with IEC 62852:2014/AMD1:2020)
()
40 A
()
Rated current (6,0 mm²)
39 A
()
40 A
()
Brands
MURRELEKTRONIK
()
Other brands
()
PHOENIX CONTACT
()
SIEMENS
()
Vendors
No vendors found
Industrial Connectors ()
All prices without tax
All prices with tax
10 25 50
0%
PH 2,5/ 8 Cable housing
N
3209756 PH 2,5/ 8 Cable housing
255€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 2,5/10 Cable housing
N
3209769 PH 2,5/10 Cable housing
293€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 2,5/11 Cable housing
N
3209772 PH 2,5/11 Cable housing
305€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 2,5/14 Cable housing
N
3209808 PH 2,5/14 Cable housing
338€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-12
pcs.
0%
PC-CT 6/2 Coding element
N
3212308 PC-CT 6/2 Coding element
1399€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PC-CT 6/3 Coding element
N
3212309 PC-CT 6/3 Coding element
1495€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-10
pcs.
0%
PH 1,5/S/3 Cable housing
N
3212756 PH 1,5/S/3 Cable housing
178€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 1,5/S/4 Cable housing
N
3212769 PH 1,5/S/4 Cable housing
189€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-12
pcs.
0%
PH 1,5/S/5 Cable housing
N
3212772 PH 1,5/S/5 Cable housing
198€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 1,5/S/6 Cable housing
N
3212785 PH 1,5/S/6 Cable housing
208€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-12
pcs.
0%
PH 1,5/S/7 Cable housing
N
3212798 PH 1,5/S/7 Cable housing
221€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-10
pcs.
0%
PH 1,5/S/8 Cable housing
N
3212808 PH 1,5/S/8 Cable housing
246€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-12
pcs.
0%
PH 1,5/S/9 Cable housing
N
3212811 PH 1,5/S/9 Cable housing
256€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-12
pcs.
0%
PH 1,5/S/10 Cable housing
N
3212824 PH 1,5/S/10 Cable housing
283€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 1,5/S/12 Cable housing
N
3212840 PH 1,5/S/12 Cable housing
303€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 1,5/S/14 Cable housing
N
3212866 PH 1,5/S/14 Cable housing
325€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
PH 1,5/S/15 Cable housing
N
3212879 PH 1,5/S/15 Cable housing
335€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
SUBCON 15 HD/M-SH D-SUB bus connector
N
5604602 SUBCON 15 HD/M-SH D-SUB bus connector
10565€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
SUBCON 15 HD/F-SH D-SUB bus connector
N
5604603 SUBCON 15 HD/F-SH D-SUB bus connector
10565€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-20
pcs.
0%
SH-8EPD68A8LB2S Cable connector
N
1157072 SH-8EPD68A8LB2S Cable connector
5597€ 0 €
inquiry
only
available
100+
inquiry
0
2026-11-25
pcs.
0%
SH-8ESD68A8LB2S Cable connector
N
1157073 SH-8ESD68A8LB2S Cable connector
5597€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-19
pcs.
0%
PV-FT-C3F-C-2,5-4-VPE50 Crimp contact
N
1196767 PV-FT-C3F-C-2,5-4-VPE50 Crimp contact
061€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-19
pcs.
0%
PV-FT-C3M-C-6-VPE50 Crimp contact
N
1196768 PV-FT-C3M-C-6-VPE50 Crimp contact
061€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-19
pcs.
0%
PV-FT-C3M-C-2,5-4-VPE50 Crimp contact
N
1196770 PV-FT-C3M-C-2,5-4-VPE50 Crimp contact
061€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-19
pcs.
0%
PV-FT-C3M-C-6-VPE250 Crimp contact
N
1196771 PV-FT-C3M-C-6-VPE250 Crimp contact
061€ 0 €
inquiry
only
available
100+
inquiry
0
2026-10-19
pcs.