Nominal input voltage UIN
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)
Test voltage: 5 V supply of the local bus (UBus) / functional ground
Note on dimensions
The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Connection method
Bus base module
Push-in connection
Description of the input
IO-Link ports in digital input (DI) mode
Number of inputs
max. 8 (IEC 61131-2 type 1)
Connection technology
2-, 3-conductor
3-conductor
Nominal input voltage U<sub>IN</sub>
Input voltage range "0" signal
Input voltage range "1" signal
Sensor current per channel
Output description
IO-Link ports in digital output (DO) mode
Nominal current per channel
Mounting position
any (no temperature derating)
Scope of supply
including bus base module and Axioline F connectors
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Maximum power dissipation for nominal condition
Nominal voltage for I/O supply
Supply voltage range
18 V DC ... 30 V DC (including all tolerances, including ripple)
Nominal current for every IO-Link port
1 A (at L+/L-)
200 mA (at C/Q)
Protective circuit
Overload protection for L+; electronically limited to 1.2 A
Reverse polarity protection; parallel diode; with external 5 A fuse (only for commissioning)
Short-circuit protection for L+; by switching off after 5 ms
Surge protection; electronic (35 V, 0.5 s)
Supply voltage
24 V DC
5 V DC (via bus base module)
Current draw
max. 50 mA
max. 60 mA (without connected peripherals)
max. 8 A (in total, current consumption of I/O circuit and at C/Q as DO and at L+/L-)
Current consumption
typ. 46 mA (without connected peripherals)
Protection
max. 8 A (polarity reversal protection up to 5 A)
Test voltage: 5 V supply of the local bus / 24 V supply (I/Os)
Test voltage: 5 V supply of the local bus (U<sub>Bus</sub>) / functional ground
Test voltage: 24 V supply (I/O) / functional ground