Input voltage range
300 V DC ... 600 V DC
3x 340 V AC ... 440 V AC
Input current
3x 12 A (600 V DC)
3x 20 A (300 V DC)
3x 32 A (400 V AC)
3x 36 A (340 V AC)
Nominal power consumption
Rated short-time current carrying capacity (ICW)
Rated peak withstand current (IPK)
Short-circuit current rating (SCCR)
Supply system configuration
DC grid
Star network (TN, TT, IT (PE))
Derating
< 350 V DC (60 W/V DC)
> 45 °C (0.5 kW/K)
> 45 °C (1.65 A/K)
Nominal input voltage range
Efficiency
> 96.5 % (400 V AC, 50 % < P<sub>Out</sub> < 100 %)
> 97 % (600 V DC, P<sub>Out</sub> > 50 %)
Power dissipation standby
Protection against overvoltage at the output (OVP)
Control deviation
± 0.2 % (Input voltage change ±20 %)
< 1 % (Current deviation Static load change 20 % ... 100 %)
Overshoot behavior
< 1 % (Switch-on procedure)
Position marking
1x +/-, 1x +/-, 1x +/-
2x L1, 2x L2 (PE), 2x L2, 2x L3 (PE), 2x L3, 2x L1 (PE)
Connection method
2x RJ45
Push-in connection
flexible with ferrule without plastic sleeve
flexible with ferrule with plastic sleeve
Stripping length
10 mm (Rigid/flexible/ferrule)
Number of power modules as CAN bus devices
Electrical isolation between input and output
Insulation voltage input/output
4240 V DC (Reinforced insulation)
Insulation voltage input, output / housing
2614 V DC (Basic insulation)
Insulation voltage input, output/signal, communication
4242 V DC (Reinforced insulation)
Insulation voltage signal, communication/housing
707 V DC (Basic insulation)