Connection method
COMBICON connectors
RJ45 jack
SMA (female)
Supply voltage range UM
24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Segment circuit supply US
24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Current consumption from UM
Input voltage range
-0.5 V DC ... 30 V DC
-0.5 V DC ... 5 V DC (“0” signal)
15 V DC ... 30 V DC (“1” signal)
Current consumption from US
Power supply at UM
max. 8 A DC (sum of U<sub>M </sub>+ U<sub>S</sub>)
Resistance to permanent reverse voltage
Power supply at US
max. 8 A DC (sum of U<sub>M </sub>+ U<sub>S</sub>)
Maximum output current per channel
Output name
AC charging locking system
Maximum output voltage
12 V DC (Internal supply)
Conductor cross-section rigid
Conductor cross-section flexible
Conductor cross-section AWG
Interface
CAN bus
Ethernet
Ethernet (2x)
RS-232
RS-485 2-wire
Note
Deactivated in HW revision 05/SW version 2.27
Standards/regulations
DIN SPEC 70121
IEC 61851-1
IEC 61851-1, Annex A+B
IEC 61851-23
Charging mode
Mode 3, Case B + C
Mode 4
Proximity
Analog input, reserved for future applications
Temperature sensors
1x Pt 1000 (evaluation via application program)
2x Pt 1000
Relay output
AC charging enabled
DC charging enabled
Maximum switching voltage
Locking control
Relay output, supplied internally
Maximum current for locking actuators
Activation time
Can be set via application program
Behavior in the event of voltage drop
Switching thresholds
Can be set via application program
Number of interfaces
1 (Transparent mode, CAN 2.0a, 11 Bit Object Identifier, CAN 2.0b, 29 Bit Object Identifier)
2
Transmission length
max. 100 m
max. 3 m (with shielded cable max. 30 m)
Termination resistor
120 Ω (Can be connected internally)
Transmission speed
125 kbps, 250 kbps, 1000 kbps (adjustable)
500 kbps (Default)
RAM
1 Mbyte (Program memory, 86 K instructions (IL))
min. 4 Mbyte (Configuration memory according to the storage medium)
Data storage system
1 Mbyte
48 kByte (retentive)