CCCex note
Use in potentially explosive areas is not permitted in China.
MTTF
121 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
301 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
693 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTBF
1004 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
199 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Electrical isolation
VCC, RS-232 // RS-422, RS-485 // DSL (A) // DSL (B) // FE
Maximum power dissipation for nominal condition
Test voltage data interface/power supply
1.5 kV<sub>rms</sub> (50 Hz, 1 min.)
500 V AC (In accordance with EN/IEC 60079-7)
Supply voltage range
18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Nominal supply voltage
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply)
5 V DC (configuration only, via mini-USB type B)
Typical current consumption
Max. current consumption
≤ 2 A (For operation in a joining station, via the DIN rail connector)
Management
User-friendly software: Guided configuration, plausibility checks, diagnostic functions, log book
Status and diagnostic indicators
LEDs: VCC (supply voltage), RD/TD (serial data traffic), ERR (errors), TERM (termination resistor active), RS-232 (RS-232 active)<br/>2 x LINK / 2 x STAT (DSL data traffic port A and port B), DIAG (diagnostic messages)
Voltage output signal
18 V DC ... 30 V DC (depending on the operating voltage)
Current output signal
≤ 150 mA (Short-circuit-proof)
Connection method
2 x 2-pos. COMBICON plug-in screw terminal blocks
COMBICON plug-in screw terminal block
D-SUB 9 plug
Mini-USB type B, 5-pos.
Plug-in/screw connection via COMBICON
Signal
Modbus
RS-232
RS-422
RS-485
Serial transmission speed
0.11/0.3/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4 kbps, NRZ
1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ
2-wire operation: 32 kbps ... 15.3 Mbps
4-wire operation: 64 kbps ... 30 Mbps
Transmission length
< 5 m (only for configuration and diagnostics)
≤ 1200 m
≤ 20 km (Depending on data rate and cable cross section)
max. 15 m
Termination resistor
390 Ω - 180 Ω - 390 Ω (can be connected)
Data flow control/protocols
Automatic control // Modbus RTU/ASCII
Software handshake, Xon/Xoff, hardware handshake (RTS/CTS), 3964R-compatible, Modbus (RTU/ASCII), transparent protocol - additional protocols supported
Single conductor/terminal point, rigid
Single-wire/terminal point, flexible
Max. AWG conductor cross-section, flexible
Min. AWG conductor cross-section, flexible
Single-wire/terminal point, rigid AWG max.
Single-wire/terminal point, rigid AWG min.
File format/coding
Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length
Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length
Protocols supported
Transparent, including 3964R protocol
Flammability rating according to UL 94
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6
Operation: 5g, 10...150 Hz, 2.5 h, in XYZ direction
Shock in accordance with EN 60068-2-27/IEC 60068-2-27
Operation: 15g, 11 ms period, half-sine shock pulse
Ambient temperature (operation)
-20 °C ... 45 °C (aligned without spacing and supply of other modules via the device, 1.5 A)
-20 °C ... 50 °C (Mounted in rows with zero spacing)
-20 °C ... 55 °C (Mounted in rows with zero spacing and low power dissipation of aligned modules)
-20 °C ... 60 °C (Freestanding (40 mm spacing to the right and left), no supply of other modules via the device)
Ambient temperature (storage/transport)
Altitude
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
10 % ... 95 % (non-condensing)
Certificate
CE-compliant
PxCIF11ATEX2313643X
PxCIMA22UKEX2313643X