CCCex note
Use in potentially explosive areas is not permitted in China.
Flammability rating according to UL 94
Basic functions
PSE/Midspan, compliant with IEEE 802.3af, at
Serial transmission speed
Frequency range
0.15 MHz ... 80 MHz
125 MHz
80 MHz ... 3 GHz (Test Level 3)
Connection method
Push-in connection
RJ45 jack
Note on the connection method
Transmission length
100 m (including patch cables)
MTTF
1397 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
3062 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
558 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Maximum power dissipation for nominal condition
12 W (at 18 V DC)
9 W (24 V DC ... 48 V DC)
Test voltage data interface/power supply
Nominal supply voltage
24 V DC (SELV/PELV, restrictions for ATEX applications)
48 V DC
Max. current consumption
1.34 A (48 V DC, Ex areas in accordance with UL-HazLoc)
2.73 A (24 V DC, Ex areas in accordance with UL-HazLoc)
4.2 A
Protective circuit
Reverse polarity protection
Conductor cross-section, flexible, with ferrule, without plastic sleeve
Conductor cross-section, flexible, with ferrule, with plastic sleeve
Single conductor/terminal point, rigid
Single-wire/terminal point, flexible
Conductor cross-section, flexible [AWG]
Degree of protection
IP20 (Manufacturer's declaration)
Ambient temperature (operation)
-40 °C ... 45 °C (75°C, observe derating)
Ambient temperature (storage/transport)
Altitude
≤ 2000 m (Restrictions for ATEX applications)
≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Air pressure (operation)
80 kPa ... 110 kPa (Restrictions for ATEX applications)
Certificate
CE-compliant
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
PxCIF19ATEX2703010X
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
Identification
Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
IEEE 802.3af
IEEE 802.3at
ISA-S71.04-1985 G3 Harsh Group A
II 3 G Ex ec IIC T4 Gc
Note
Please follow the special installation instructions in the documentation!
Electromagnetic compatibility
CISPR 22
Conformance with EMC Directive 2014/30/EU
FCC Part 15B Class A
Standards/regulations
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-6-3
EN 61000-6-4