Your Language:
English (en)
en
English
lt
Lietuviškai
Debug
Administrator
Testing
did you mean:
Show more results in separate page
0 items
000
Your basket is empty
Total price for 0 items 000
All prices without tax
All prices with tax
Order
Proceed to basket details
TRIO-PS-2G/1AC/12DC/5/C2LPS Power supply
N
0%
2903157

TRIO-PS-2G/1AC/12DC/5/C2LPS Power supply

Manufactured by
Brand PHOENIX CONTACT
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/5 A C2LPS
4055626248486
only
available
100+
1364
pcs.
()
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
16180 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
1364
pcs.
Properties
Description
Dimensions
Files
Codes
Inrush current integral (I2t)
< 0.6 A<sup>2</sup>s
Network type
Star network
Nominal input voltage range
100 V AC ... 240 V AC
110 V DC ... 250 V DC
Setting range of the output voltage (USet)
12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
Input voltage range
100 V AC ... 240 V AC -15 % ... +10 %
99 V DC ... 275 V DC
Nominal output current (IN)
5 A
Input voltage range AC
85 V AC ... 264 V AC
Electric strength, max.
≤ 300 V AC 15 s
Typical national grid voltage
120 V AC
230 V AC
Voltage type of supply voltage
AC
DC
Inrush current
≤ 25 A (typical)
Inrush current integral (I&lt;sup&gt;2&lt;/sup&gt;t)
< 0.6 A<sup>2</sup>s
Inrush current limitation
typ. 25 A (after 1 ms)
AC frequency range
50 Hz ... 60 Hz ±10 %
Mains buffering time
typ. 110 ms (230 V AC)
typ. 20 ms (120 V AC)
Current consumption
0.3 A (250 V DC)
0.6 A (230 V AC)
0.6 A (240 V AC)
0.7 A (110 V DC)
1 A (120 V AC)
1.1 A (100 V AC)
Nominal power consumption
137.3 VA
Protective circuit
Transient surge protection; Varistor
Power factor (cos phi)
0.51
Typical response time
< 1 s
Input fuse
6.3 A Slow-blow
Recommended breaker for input protection
6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE
< 0.25 mA
Switch-on voltage
≥ 85 V DC
Shut-down voltage
< 80 V DC
Efficiency
> 86 % (for 230 V AC and nominal values)
Output characteristic
U/I with dynamic load reserve
Nominal output voltage
12 V DC ±1 %
Setting range of the output voltage (U&lt;sub&gt;Set&lt;/sub&gt;)
12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (I&lt;sub&gt;N&lt;/sub&gt;)
5 A
Derating
> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance
< 25 V
Protection against overvoltage at the output (OVP)
≤ 22 V DC
Control deviation
< 0.1 % (change in input voltage ±10 %)
< 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
Residual ripple
< 50 mV<sub>PP</sub> (with nominal values)
Output power
60 W
Maximum no-load power dissipation
< 1 W (230 V)
Power loss nominal load max.
< 10 W (230 V)
Rise time
≤ 10 ms (U<sub>OUT</sub> (10 % ... 90 %))
Connection in parallel
yes, for redundancy and increased capacity
Connection in series
yes
Maximum switching voltage
30 V AC/DC
Continuous load current
100 mA
Connection method
Push-in connection
Conductor cross-section, rigid min.
0.2 mm²
Conductor cross-section, rigid max.
1.5 mm²
4 mm²
Conductor cross-section flexible min.
0.2 mm²
Conductor cross-section flexible max.
1.5 mm²
2.5 mm²
Conductor cross-section AWG min.
24
Conductor cross-section AWG max.
12
16
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27040701
ECLASS-15.0
27040701
ETIM 10.0
EC002540
UNSPSC 21.0
39121000
GTIN
4055626248486
Item accessories
0%
PLT-SEC-T3-230-FM-PT Type 3 surge protection device
N
2907928 PLT-SEC-T3-230-FM-PT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
599
pcs.
0%
PLT-SEC-T3-24-FM-PT Type 3 surge protection device
N
2907925 PLT-SEC-T3-24-FM-PT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
1520
pcs.
No related items found