QUINT4-PS/1AC/48DC/10/CO Power supply
N
0%
2904626

QUINT4-PS/1AC/48DC/10/CO Power supply

Manufactured by
Brand PHOENIX CONTACT
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, NFC interface, and protective coating, input: 1-phase, output: 48 V DC / 10 A
4055626939216
only
available
100+
1695
pcs.
()
Supply from Phoenix Contact’s warehouse
Product recommended retail price (RRP) is
000
52480 0 € pcs.
All prices without tax
All prices with tax
inquiry
only
available
100+
inquiry
1695
pcs.
Properties
Description
Dimensions
Files
Codes
Control input (configurable) Rem
Output power ON/OFF (SLEEP MODE)
Inrush current integral (I2t)
< 0.4 A<sup>2</sup>s
Default
24 V DC 20 mA 24 V DC for P<sub>Out</sub> < P<sub>N</sub>
24 V DC 20 mA 24 V DC for U<sub>Out</sub> > 0.9 x U<sub>Set</sub>
closed (U<sub>out</sub> > 0.9 U<sub>Set</sub>)
Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)
Frequency range (fN)
16.7 Hz (acc. to EN 50163)
50 Hz ... 60 Hz -10 % ... +10 %
Nominal input voltage range
100 V AC ... 240 V AC
110 V DC ... 250 V DC
Setting range of the output voltage (USet)
48 V DC ... 56 V DC (constant capacity)
Input voltage range
100 V AC ... 240 V AC -15 % ... +10 %
110 V DC ... 250 V DC -18 % ... +40 %
Nominal output current (IN)
10 A
Derating
< 100 V AC (1 %/V)
< 110 V DC (1 %/V)
> 60 °C (2.5 %/K)
Static Boost (IStat.Boost)
12.5 A
Dynamic Boost (IDyn.Boost)
15 A (5 s)
Electric strength, max.
300 V AC 60 s
Selective Fuse Breaking (ISFB)
60 A (15 ms)
Typical national grid voltage
120 V AC
230 V AC
POut
> 100 % (LED lights up yellow, output power > 480 W)
> 50 % (LED lights up green, output power > 240 W)
> 75 % (LED lights up green, output power > 360 W)
Voltage type of supply voltage
AC
DC
Inrush current
typ. 11 A (at 25 °C)
UOut
< 0.9 x U<sub>Set</sub> (LED flashes green)
> 0.9 x U<sub>Set</sub> (LED lights up green)
Inrush current integral (I&lt;sup&gt;2&lt;/sup&gt;t)
< 0.4 A<sup>2</sup>s
Inrush current limitation
11 A (after 1 ms)
AC frequency range
50 Hz ... 60 Hz -10 % ... +10 %
Frequency range (f&lt;sub&gt;N&lt;/sub&gt;)
16.7 Hz (acc. to EN 50163)
50 Hz ... 60 Hz -10 % ... +10 %
Mains buffering time
typ. 32 ms (120 V AC)
typ. 32 ms (230 V AC)
Current consumption
2.5 A (250 V DC)
2.7 A (240 V AC)
2.8 A (230 V AC)
5.5 A (120 V AC)
6 A (110 V DC)
6.8 A (100 V AC)
Nominal power consumption
519 VA
Protective circuit
Transient surge protection; Varistor, gas-filled surge arrester
Switch-on time
< 1 s
Typical response time
300 ms (from SLEEP MODE)
Input fuse
12 A (slow-blow, internal)
Recommended breaker for input protection
10 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE
< 3.5 mA
1.3 mA (264 V AC, 60 Hz)
Efficiency
typ. 94 % (120 V AC)
typ. 95 % (230 V AC)
Output characteristic
FUSE MODE
Smart HICCUP
U/I Advanced
Nominal output voltage
48 V DC
Setting range of the output voltage (U&lt;sub&gt;Set&lt;/sub&gt;)
48 V DC ... 56 V DC (constant capacity)
Nominal output current (I&lt;sub&gt;N&lt;/sub&gt;)
10 A
Static Boost
12.5 A
Dynamic Boost (I&lt;sub&gt;Dyn.Boost&lt;/sub&gt;)
15 A (5 s)
Selective Fuse Breaking (I&lt;sub&gt;SFB&lt;/sub&gt;)
60 A (15 ms)
Magnetic circuit breaker tripping
A1...A13 / B2...B6 / C1...C3 / Z1...Z10
Feedback voltage resistance
≤ 60 V DC
Protection against overvoltage at the output (OVP)
≤ 60 V DC
Control deviation
< 0.25 % (change in input voltage ±10 %)
< 0.5 % (Static load change 10 % ... 90 %)
< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz))
Residual ripple
< 70 mV<sub>PP</sub> (with nominal values)
Short-circuit-proof
yes
No-load proof
yes
Output power
480 W
600 W
720 W
Apparent power
644 VA (230 V, U<sub>OUT</sub> = 48 V, I<sub>OUT</sub> = stat. Boost)
660 VA (120 V, U<sub>OUT</sub> = 48 V, I<sub>OUT</sub> = stat. Boost)
Maximum no-load power dissipation
< 5 W (120 V AC)
< 5 W (230 V AC)
Power loss nominal load max.
< 28 W (230 V AC)
< 36 W (120 V AC)
Length
0
m
Width
0
m
Height
0
m
Weight Net
0
kg
Weight
0
kg
Package
0
kg
Volume
0
No files found
ECLASS-13.0
27040701
ECLASS-15.0
27040701
ETIM 10.0
EC002540
UNSPSC 21.0
39121000
GTIN
4055626939216
Item accessories
0%
UWA 182/52 Mounting adapter
N
2938235 UWA 182/52 Mounting adapter
1940 0 €
only
available
100+
inquiry
2760
pcs.
0%
UWA 130 Mounting adapter
N
2901664 UWA 130 Mounting adapter
1770 0 €
only
available
100+
inquiry
738
pcs.
0%
TWN4 MIFARE NFC USB ADAPTER Programming adapter
N
2909681 TWN4 MIFARE NFC USB ADAPTER Programming adapter
18470 0 €
only
available
100+
inquiry
0
pcs.
0%
PLT-SEC-T3-230-FM-UT Type 3 surge protection device
N
2907919 PLT-SEC-T3-230-FM-UT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
0
pcs.
0%
PLT-SEC-T3-60-FM-UT Type 3 surge protection device
N
2907917 PLT-SEC-T3-60-FM-UT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
75
pcs.
0%
PLT-SEC-T3-230-FM-PT Type 3 surge protection device
N
2907928 PLT-SEC-T3-230-FM-PT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
599
pcs.
0%
PLT-SEC-T3-60-FM-PT Type 3 surge protection device
N
2907926 PLT-SEC-T3-60-FM-PT Type 3 surge protection device
12930 0 €
only
available
100+
inquiry
0
pcs.
No related items found