Color (Housing)
white aluminium (RAL 9006)
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Note on the connection method
Auto negotiation and autocrossing
Transmission length
100 m (Between transmitter / receiver)
No. of channels
1 (RJ45 port)
4 (RJ45 PoE ports)
Product family
Unmanaged PoE Switch 1000
MTTF
72.1 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%)
Special properties
Extended temperature range
Basic functions
Store-and-forward switch, 10/100/1000 Mbps, auto negotiation, redundant power supply, PoE according to IEEE 802.3at/802.3af, jumbo frames up to 10240 bytes, alarm contact
Signal contact control voltage
Signal contact control current
Status and diagnostic indicators
LEDs: U<sub>S1</sub>, U<sub>S2</sub> (redundant voltage supply), Alarm (alarm contact), Link/Activity and PoE per Ethernet port
Local diagnostics
Alarm Power failure at US1 or US2/Link failure
LNK/ACT Link status/data transmission Green LED
PoE PoE detection Orange LED
US1, US2 Supply voltage Green LED
Maximum power dissipation for nominal condition
Power supply connection
Via COMBICON, max. conductor cross-section 2.5 mm²
Inrush current
32.1 A (24 V DC for 3540 μs)
Residual ripple
3.6 V<sub>PP</sub> (within the permitted voltage range)
Max. current consumption
6.93 A (Maximum, nominal load)
Typical current consumption
165 mA (at U<sub>S</sub> = 24 V DC)
Conductor cross-section, rigid
Conductor cross-section, flexible
Conductor cross-section AWG
Ambient temperature (operation)
Ambient temperature (storage/transport)
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
5 % ... 95 % (non-condensing)
Air pressure (operation)
57 kPa ... 108 kPa (up to 4850 m above mean sea level)
Air pressure (storage/transport)
57 kPa ... 108 kPa (up to 4850 m above mean sea level)
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC
Conformance with EMC directives
EN 55022 (emitted interference) Criterion A
IEC 61000-4-3 (immunity to radiated interference) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion B
IEC 61000-4-6 (immunity to conducted interference) Criterion A
IEC 61000-4-8 (immunity to magnetic fields) Criterion A
IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B